3. INSTALLING BRACKETS
Install the brackets with nuts, washers and spring
washers (Fig. 17).
Fig.17
Spring washer
Special nut
Bracket (Left)
4. INSTALLING INDOOR UNIT
Reset the hex bolts as shown in Fig. 18.
Fig.18
Indoor unit
Apply the indoor unit to the brackets (Fig. 19).
Fig.19
Bolt
Indoor unit
Now, securely tighten the hex bolts in both sides.
5. INSTALL THE DRAIN HOSE
Select whether the drain hose will be connected to the
left or right side (Fig. 5).
Insert the drain hose into the drain pan, then secure
the drain hose with a nylon fastener (Fig. 8).
Wrap the insulation (drain hose) around the drain
hose connection (Fig. 9).
Be sure to arrange the drain hose so that it is leveled
lower than the drain hose connecting port of the
indoor unit (Fig. 20).
Bracket
Bracket (Right)
Hex bolt
5/16" to 1/2"
(8 to 13mm)
Bracket
– –
Fig. 20
Remove the hole cover.
Arrange the drain hose
lower than this portion.
OK
When drain hose is arranged backward.
Secure the drain hose with the VT wire (Fig.21).
Fig. 21
Piping hole
VT wire
hole
Cut the grille
Pass the drain hose
through here.
3. OUTDOOR UNIT INSTALLATION
• When the outdoor unit will be exposed to strong
wind, fasten it with bolts at the places indicated by
the arrows. (Fig. 22)
• Since the drain water flows out of the outdoor unit
during heating operation, install the drain pipe sold
separately and connect it to an commercial 16 mm
hose. (Heat & Cool model only)
• When installing the drain pipe, plug all the holes (•
holes at two places) other than the drain pipe
mounting hole in the bottom of the outdoor unit
with putty so there is no water leakage. (Fig. 22)
(Heat & Cool model only)
Fig. 22
– 150 –
Drain hose
NO
VT wire
Base (Bottom)
Intake
grille
Drain hose

Hide quick links: