Technical Data

The following table lists input values for the appliance.
Burner
Orifice Size
I
MAIN
58 (1.07mm)
BACK
58 (1.07mm)
SIDE
66 (0.84mm)
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with following list.
Gas Category
Orifice Sizes (see above)
Gases / Pressures
Countries
Do not tamper with or modify regulator. Use only regulators, which supply the pressure, listed in the table
above. A regulator of 28-30mbar must be used for butane or a 37mbar regulator for propane. For grills set
up to operate at 50mbar, the grill is equipped with an internal regulator. This internal regulator has an outlet
pressure of 30mbar and must not be modified or adjusted. For replacement, use only the regulator specified
by the manufacturer: Maxitrol model number RV47LSMF.
Leak Testing Instructions
WARNING!
A leak test must be performed annually and each time a cylinder is hooked up or if a part
of the gas system is replaced.
WARNING!
Never use an open flame to check for gas leaks. Be certain no sparks or open flames are
in the area while you check for leaks. Sparks or open flames will result in a fire or explosion, damage to
property, serious bodily injury, or death.
Leak testing: This must be done before initial use, annually, and whenever any gas components are replaced
or serviced. Do not smoke while performing this test, and remove all sources of ignition. See Leak Testing Diagram
for areas to check. Turn all burner controls to the off position. Turn gas supply valve on.
Brush a half-and-half solution of liquid soap and water onto all joints and connections of the regulator,
hose, manifolds and valves.
Bubbles will indicate a gas leak. Either tighten the loose joint or have the part replaced with one recommended
by the Napoleon Customer Care department and have the grill inspected by a certified gas installer.
If the leak cannot be stopped, immediately shut off the gas supply, disconnect it, and have the grill inspected
by a certified gas installer or dealer. Do not use the grill until the leak has been corrected.
(Gross) Heat Input (Total)
19.2 kW
5.3 kW
2.8 kW
I
I
3B/P(30)
3+(28-30/37)
I
I
Butane 30mbar
Butane 28-30mbar
Propane 30mbar
Propane 37mbar
DK, FI, NL, NO,
BE, ES, FR, GB, IE,
SE
IT, PT
Gas Usage (Total)
1396 g/h
385 g/h
204 g/h
I
3B/P(50)
I
Butane 50mbar
Propane 50mbar
DE, AT
www.napoleongrills.com
5