Technical Data

The following table lists input values for the appliance.
R365
R425
Certified Gases / Pressures - Check rating plate to ensure that it corresponds with the following list.
Do not tamper with or modify regulator. Use only regulators which supply the pressure listed in the table
above. For replacement, use only the regulator specified by the manufacturer.
N415-0574CE-GB-DE AUG 07.19
N415-0574CE-GB-DE AUG 07.19.indd 7
Do not route hose underneath drip pan.
Do not route hose between space in bottom shelf and back panel.
Do not route hose over top of back panel.
Ensure all connections are tightened using two wrenches. Do not use Teflon tape or pipe dope on any
hose connection.
Ensure the hose does not contact any high temperature surfaces, or it may melt and leak causing a fire.
Do not use enclosure to store excess hose, as there is a greater chance of the hose contacting a hot
surface, it may melt and leak causing a fire.
Burner
Orifice Size
I
Main
1.11mm
Side (Infra
0.86mm
Red)
Side (Flame)
0.86mm
Burner
Orifice Size
I
Main
#59
Side (Infra
0.86mm
Red)
Side (Flame)
0.86mm
Gas Category
Orifice Sizes(see above)
Butane 30mbar
Gases / Pressures
Propane 30mbar
BE, BG, CY, DK, EE,
FI, FR, GB, HR, HU,
Countries
IS, IT, LT, LU, MT,
NL, NO, RO, SE, SI,
SK, TR
(Gross) Heat Input
(Total
II
I / II
#62
10.5 kW
#69
3.0 kW
#69
3.0 kW
(Gross) Heat Input
(Total
II
I / II
#64
14.25 kW
#69
3.0 kW
#69
3.0 kW
I
I
3B/P(30)
3+(28-30/37)
I
I
Butane 28-30mbar
Propane 37mbar
BE, CH, CY, CZ, ES, FR,
GB, GR, IE, IT, LT, LU,
LV, PT, SK, SI
Gas Usage (Total)
I / II
764 g/hr
218 g/hr
218 g/hr
Gas Usage (Total)
I / II
1037 g/hr
218 g/hr
218 g/hr
I
3B/P(50)
II
Butane 50mbar
Propane 50mbar
AT, CH, DE, SK