Installation steps
Commissioning and testing
1. Fasten the cover panel onto the
boiler
2. Pivot the control unit upwards.
3. Hang the front panel to the wall
mounting frame by the appropriate
hook.
4. Press down the front panel at the
bottom.

Adjusting the boiler water temperature

The boiler water temperature must be set at an adequate level to satisfy the
requirements of the heating system.

Final checks

1. If a time switch has been built into
the control unit:
Set required activation periods as
per the time switch operating
instructions.
Time switch operating
instructions
46
(cont.)
5. Insert the screw at the top of the
boiler.
Note
The outer case forms a seal with
the combustion box. It must there-
fore be securely fitted with the
screw provided.
Selecting the boiler water tempera-
ture:
Set rotary selector tr to the desired
CH temperature.
2. Fill in the relevant details for the
installation in the benchmark log-
book supplied in the instructions
pack and affix the self adhesive bar
code strip from the outside of the
boiler packaging to this logbook.