Trouble Shooting; Installation - Vulcan-Hart RE-3 Owner's Manual

Electric solid top oven range
Table of Contents

Advertisement

TROUBLE SHOOTINg:

COMpLAINT
Not switching on.

INSTALLATION:

1) Before leaving the factory, the unit has been fully assembled and undergone
final tests.
2) Unit must be installed on a fire proof floor. If the floor is of wood, arrangements must
be made to comply with local fire regulations.
3) Remove plastic material protecting the stainless steel panels.
4) Position the unit. Check with a spirit level and use floor adjusters on legs to bring to
the correct level if necessary.
5) An electrical isolator switch must be incorporated in the supply line and fitted adjacent
to the unit.
6) Before connecting the electrical supply to the unit, check voltage details correspond
with the data plate positioned at the front bottom right hand corner of the unit.
7) for access to main terminals behind right hand control panel, remove the three
Screws fixing the side panel and the two screws fixing the panel to the door frame.
Connect the 3 phase wires to circuit breakers, neutral wire to neutral block and the
earth wire to earth connection. Ensure that the unit is effectively earthed.
8) NOTE: Before operating the boiling top, switch hotplates to low position (1) to burn
off manufacturing residues. During this operation, smoke may be emitted from
the unit.
9) The unit is not intended for use by persons (including children) with reduced physical,
sensory or mental capabilities, or lack of experience and knowledge unless they
have been given supervision or instruction concerning use of the appliance by a
person responsible for their safety.
10) Children should be supervised to ensure that they do not play with the appliance.
pLEASE NOTE
11) The installation of the equipment must be done by a qualified registered
technician all in compliance with statutory Health and Safety Regulations.
Vulcan catering equipment (ptY)ltD
pOSSIBLE CAUSE
Main isolator off.
Main circuit breaker off.
[ 5 ]
REMEdy
Switch isolator on.
Switch main circuit breaker on.
Ranges RE-3 and RE-3-T
REV3-11-2011 / VfM29