1. SERVICE CALL CONDITIONS

This copier provides the following five types of service call (SC) conditions
that help minimize the possibility of system down time.
TYPE 1: Safety Action
TYPE 2: Immediate Stop
TYPE 3: Stop
TYPE 4: Unit Failure
TYPE 5: Logging Only
Type 1 SCs (Safety Action) can be reset by taking the following action:
SCs for fusing unit failure:
Enter SP5-810-1 (Fusing SC Reset), select "1" (Reset), and turn the
power off and on.
Other Type 1 SCs:
Enter SP5-810-2 (SC Reset), select "1" (Reset), and turn the power off
and on.
All SCs are logged.
SM
Immediately stops the copier and displays an SC. Turning
the power off and on cannot recover the copier.
Immediately stops the copier and displays an SC. Turning
the power off and on can recover the copier.
Displays an SC after any necessary machine operation is
completed. Turning the power off and on can recover the
copier.
Displays an SC only when a faulty function is selected.
Turning the power off and on can recover the copier.
Neither displays an SC nor stops the copier. Only logs these
SCs. Logged SCs can be displayed in the SP mode.