Asko TD70.1 SPO Installation Instructions Manual page 9

Domestic vented tumble dryer
Table of Contents

Advertisement

Installation instructions
Connecting a 3-wire Power Cord
WARNING!
Before starting this procedure, be sure the
power is turned off at the breaker/fuse box.
Ground
Power Supply Cord
You will need a 3-wire power supply cord with
three No. 10 copper wires and a matching
3-wire receptacle of NEMA Type 10-30R, as
illustrated below:
To connect a 3-wire power cord to the dryer,
follow the steps below.
NOTE!
The numbers in the illustration correlate to the
step numbers.
1. Turn the power off at the breaker or fuse box.
2. Remove terminal block cover.
3. Use the strain relief attached below the
terminal block opening.
4. Loosen or remove center terminal block
screw.
6
5. Connect ground (center) wire of power
supply cord to the center, silver-colored
terminal screw. Tighten screw.
6. Connect the other wires to outer screws.
7. Tighten the strain relief screws.
Ground
8. Replace terminal box cover on back of dryer.
(center)
9. Plug dryer into wall receptacle.
10.Turn power on at breaker/fuse box.
Connecting a 4-wire Power Cord
WARNING!
Before starting this procedure, be sure the
power is turned off at the breaker/fuse box.
Customer Care Center
1-800-898-1879
www.askona.com
4
5
9

Advertisement

Table of Contents
loading

Table of Contents