5.2
Image Quality Adjustment
D
Load the paper that has been used to register the target density into the tray.
The paper profile of the tray is automatically switched to the paper profile that has been used to register
the target density.
E
Select the tray containing paper, then
press [OK].
F
Press Start on the control panel.
A chart is printed out, and auto adjustment starts.
When the adjustment is completed, you return to
the [Maximum Density Auto Adjustment (RU)]
screen.
Adjustment processing cannot be stopped until
all charts are printed out.
G
When the adjustment is completed, you
automatically return to the [Maximum
Density Auto Adjustment (RU)] screen.
Check the adjustment result.
The auto adjustment result is displayed in
[Current Data].
H
Press [Return] to return to the [Process Adjustment Menu] screen.
Note that the tray remains set to the paper profile that has been used to register the target density.
Tips
If [Maximum Density Auto Adjustment (RU)] is carried out, the paper profile of the tray that has been used for auto
adjustment is switched to the paper profile that has been used to register the target density , and it is not returned to
the paper profile that has been used before adjustment. After the adjustment is completed, return to the original paper
profile. After completing this adjustment, you can ask your service representative to configure a setting so that the
paper profile automatically returns to that used before adjustment. For more information, contact your service
representative.
Then, carry out Color Density Manual Control (page 5-26).