3210 TIMER SETTING PROCEDURE
Typical Programming Procedure
Calculate the gallon capacity of the system, subtract the
necessary reserve requirement and set the gallons available
opposite the small white dot on the program wheel gear (Figure
3).
NOTE: Drawing shows 8,750 gallon setting. The capacity
(gallons) arrow (15) shows zero gallons remaining.
The unit will regenerate tonight at the set
regeneration time.
How To Set The Time Of Day
1. Press and hold the red button in to disengage the drive
gear.
2. Turn the large gear until the actual time of day is opposite
the time of day pointer.
3. Release the red button to again engage the drive gear.
How To Manually Regenerate Your Water Conditioner At
Any Time
1. Turn the manual regeneration knob clockwise.
2. This slight movement of the manual regeneration knob
engages the program wheel and starts the regeneration
program.
3. The black center knob will make one revolution in the
following approximately three hours and stop in the position
shown in the drawing.
4. Even though it takes three hours for this center knob to
complete one revolution, the regeneration cycle of your unit
might be set for only one half of this time.
5. In any event, conditioned water may be drawn after rinse
water stops flowing from the water conditioner drain line.
Immediate Regeneration Timers
These timers do not have a 24 hour gear. Setting the gallons
on the program wheel and manual regeneration procedure are
the same as previous instructions. The timer will regenerate as
soon as the capacity gallons reaches zero.
NOTE: The program wheel to the left may be different than
the program wheel on the product.
NOTE:To set meter capacity rotate manual knob one - 360°
revolution to set gallonage.