General Service Hints For Meter Control - Pentair Fleck 2850s Service Manual

Hide thumbs Also See for Fleck 2850s:
Table of Contents

Advertisement

GENERAL SERVICE HINTS FOR METER
CONTROL
Problem: Softener delivers hard water
Reason: Reserve capacity has been exceeded.
Correction: Check salt dosage requirements and reset
program wheel to provide additional reserve.
Reason: Program wheel is not rotating with meter output.
Correction: Pull cable out of meter cover and rotate manually.
Program wheel must move without binding and clutch must
give positive clicks when program wheel strikes regeneration
stop. If it does not, replace timer.
Reason: Meter is not measuring flow.
Correction: Check meter with meter checker.
24 • MY10 Fleck 2850s

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents