Samsung APV36M0 User & Installation Manual page 42

Table of Contents

Advertisement

Installing the air conditioner
Power specification
f Wiring standards
f
Model name
Power
Capacity of circuit breaker
Thickness of ground wire
Indoor and outdoor unit power wire
Indoor and outdoor unit communication wire
Allowable voltage
Power wire
Product
• Please use rated wires or products (with heat resistance over 105°C ) of all the wires and the switches or fuses in
the cabinet panel. (Retailer and installer is responsible for the use of parts that does not meet the wire standards or
CAUTION
capacity requirements)
• Make sure that wires doesn't make any sparks around the auxiliary power switch or installed in a place with high
temperature. (If the ambient temperature is high, allowable current of the wire will decrease and current reduction
factor will occur.)
• Please install the auxiliary power switch in a dry place and install panel board or electrical component box.
• Please install circuit breaker in the panel board.
• When connecting the main power, press the wire to the terminal to secure connection.
• Selecting solderless ring terminal
Thickness of cable (mm
42
Mirage_AP36M0@_IBIM_E_34573A(1).indd 42
Item
Indoor unit
Outdoor unit
Product
Product
mm
mm
mm
Type
Below 20m
mm
Over 20m
mm
Silver solder
2
)
6.0
10.0
APV36M0✴ Series
APV36M0AN
APV36M0AX
Single phase 230V, 60Hz
A
2
2
2
V
207 ~ 253
H07RN-F or higher
2
CV6.0 (Should be purchased separately)
CV10.0 (Should be purchased separately)
2
B (mm)
Less than 12
Less than 12
40
4.0
0.75
0.75
d2 (mm)
More than 6
More than 6
2012-02-21 오후 1:09:55