9.3.5 ACQUISITION OF ABL/WB ADJUSTMENT DATA • • • [QPW]
The command QPW is for acquiring the factory-preset data about the video of the panel.
Command
Effective Operation
A
Format
[QPW]
All operations
Data Arrangement
ECO
1
Drive sequence
2
Standard/nonstandard
3
Type of ABL/WB tables
4
ABL adjustment value
B
5
R-HIGH adjustment value
6
G-HIGH adjustment value
7
B-HIGH adjustment value
8
R-LOW adjustment value
9
G-LOW adjustment value
10
B-LOW adjustment value
11
Gamma setting
12
Streaking correction
13
Peripheral luminance correction
C
14
Reserved
15
WB interlocked with APL
16
Transition of protective operations
17
Reserved
CS
D
9.3.6 ACQUISITION OF PULSE METER VALUE • • • [QPM]
The command QPM is for acquiring the accumulated number of pulses of the panel.
Command
Effective Operation
Format
[QPM]
All operations
Data Arrangement
E
ECO
1
Pulse meter B 1
2
Pulse meter B 2
3
Pulse meter B 3
4
Pulse meter B 4
5
Pulse meter B 5
CS
F
154
1
2
Modes
To acquire data on operations of the panel Return data: 3 (ECO)+35(DATA)+2(CS)= 40 Byte
Output
Data
Example
Length
3 byte
QPW
3 byte
60V
1 byte
S
2 byte
T2
3 byte
128
3 byte
256
3 byte
256
3 byte
256
3 byte
512
3 byte
512
3 byte
512
1 byte
A
1 byte
1
1 byte
0
1 byte
1 byte
0
1 byte
0
∗∗
2 byte
2 byte
37
Modes
To acquire data on operations of the panel Return data: 3 (ECO)+40(DATA)+2(CS)= 45 Byte
Data
Output Example
Length
3 byte
QPM
8 byte
00000000
8 byte
00000000
8 byte
00000000
8 byte
00000000
8 byte
00000000
2 byte
E7
2
3
Function
1: Drive sequence
48V Video 48 Hz
50V Video 50 Hz
60V Video 60 Hz
72V Video 72 Hz
75V Video 75 Hz
60P PC 60 Hz
70P PC 70 Hz
2: Standard/
nonstandard
S
Standard
N
Nonstandard
3: Type of ABL/WB tables
Tn
n: 1 to 4
11: Gamma setting
n
0 to F
Function
PDP-427XD
3
4
Remarks
12, 15: Setting for Items 12 and 15
0
OFF
1
ON
13: Peripheral luminance
correction
0
OFF
2
ON (interlocked with APL)
16: Transition of brightness by
protective operations
0
Upper limit state for brightness
1
Brightness being reduced
2
Lower limit state for brightness
3
Brightness being increased
Remarks
4

Hide quick links: