Acquisition Of Other Data On The Panel • • • [Qip] - Pioneer PDP-4270XA Service Manual

Hide thumbs Also See for PDP-4270XA:
Table of Contents

Advertisement

5
9.3.3 ACQUISITION OF OTHER DATA ON THE PANEL • • • [QIP]
The command QIP is for acquiring data on operational information of the panel.
Command
Effective Operation
Format
Modes
[QIP]
All operations
Data Arrangement
ECO
1
SERIAL
2
HOUR METER
3
TOTAL HOUR METER
4
PON COUNTER
5
TEMP1 acquisition (Temperature value)
6
TEMP0 acquisition (Temperature value)
7
MAX-TEMP1 acquisition (Temperature value)
8
Reserved
CS
9.3.4 ACQUISITION OF PANEL ADJUSTMENT DATA (COMMON DATA) • • • [QAJ]
The command QAJ is for acquiring the panel's factory-preset data.
Command
Effective Operation
Format
Modes
[QAJ]
All operations
Data Arrangement
ECO
1
V-SUS adjustment value
2
V-OFT adjustment value
3
V-RST-P adjustment value
4
Reserved
5
XSB adjustment value
6
YSB adjustment value
7
YTG adjustment value
8
YTW adjustment value
9
RSW adjustment value
10
YTB adjustment value
11
RYW adjustment value
12
R-REVICE setting value
13
G-REVICE setting value
14
B-REVICE setting value
CS
• For each REVISE setting value, the level set for RRL, RGL, or RBL is transmitted as one character.
5
6
Function
To acquire data on operations of the panel Return data: 3 (ECO)+58(DATA)+2(CS)= 63 Byte
Data
Length
3 byte
15 byte
8 byte
8 byte
8 byte
5 byte
5 byte
5 byte
4 byte
2 byte
Function
To acquire data on operations of the panel Return data: 3 (ECO)+41(DATA)+2(CS)= 46 Byte
Data
Length Output Example
3 byte
QAJ
3 byte
128
3 byte
128
3 byte
128
∗∗∗
3 byte
3 byte
128
3 byte
128
3 byte
128
3 byte
128
3 byte
128
3 byte
128
3 byte
128
1 byte
0
1 byte
0
1 byte
0
2 byte
B7
PDP-427XD
6
7
Output Example
QIP
- - - - - - - - - - - - - - -
00000000
00000000
00000000
Note
+23.5 (*1)
(*1) : Centigrade scale
+28.7 (*1)
+78.3 (*1)
∗∗∗∗
94
7
8
Remarks
Remarks
153
8
A
B
C
D
E
F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Pdp-427xaPdp-427xdPdp-4270xd

Table of Contents