Panasonic aw-e350p Operating Instruction page 49

Hide thumbs Also See for aw-e350p:
Table of Contents

Advertisement

Note
• Only 0 dB, 9 dB, or 18 dB can be selected in case
of using the RCU.
Gain increase selector switch
Remote control unit
8. Digital Gain Up Setting
[Digital Gain Up: 0dB, 6dB, 12dB, 18dB, 24dB, 30dB]
This can be set only when "OFF" has been selected
as the auto gain up setting ( -5).
0 dB: Under normal circumstances, this setting is
used.
6 dB to 30 dB: Use this setting while shooting dark
scenes if it is not possible to achieve a satisfactory
video output even when the lens diaphragm is
opened and "Night Eye" is selected as the manual
gain up setting ( -7).
9. CCD Storage Time Setting
[Charge Time: Auto, OFF, 1/30s, 1/15s, 1/8s, 1/4s,
1/2s, 1s, 2s]
This is used to set the CCD storage time.
Auto: ALC is performed followed by AGC and then by
the data storage, and the camera automatically
adjusts the light quantity.
If "ON" is selected as the auto ND (ELC) setting
( -4), ELC is performed followed by ALC, AGC
and then by the data storage in this order, and the
light quantity is automatically adjusted.
The electronic shutter setting ( -2) cannot be
changed.
OFF: Under normal circumstances, this setting is
used.
1/30s to 2s: Use this setting if it is not possible to
achieve a satisfactory video output even when the
gain up setting is used.
The auto ND (ELC) setting ( -4) and electronic
shutter setting ( -2) go "OFF" and cannot be
changed.
K If the images (CCD read out (mode) setting ( -4))
have been set to "Fine", 1/15s to 2s is selected as
the storage time setting, and the sensitivity is set
to about one-half of that obtained with when they
have been set to "Normal".
10. Black Level Setting [Pedestal: –150 to +150]
The black level (pedestal) of the luminance (Y) signal
can be set. Used in adjusting the black levels of two
or more cameras.
- 49 -