IVT AE-X12GR-N Service Manual page 24

Room air conditioner
Hide thumbs Also See for AE-X12GR-N:
Table of Contents

Advertisement

AEX12GRN
2. Outdoor unit
Item
Mode
Compressor
Cooling
chamber ther-
Dehumidifying
mistor (TH1)
Heating
Heat exchanger
Cooling
thermistor (TH2)
Dehumidifying
Heating
Outside air tem-
Auto
perature ther-
mistor (TH3)
Cooling
Dehumidifying
Heating
Suction pipe ther-
Cooling
mistor (TH4)
Dehumidifying
Heating
2-way valve ther-
Cooling
mistor (TH5)
Dehumidifying
Heating
Control opera-
When resistance is
tion
low (temperature
judged higher than
actual)
Expansion valve
Compressor oper-
control and com-
ates, but room does
pressor protection
not become cool or
warm (expansion
valve is open).
Outdoor unit heat
Compressor operates
exchanger over-
at low speed or stops.
heat prevention
Expansion valve
Defrosting operation
control
is not activated as
Defrosting
needed, and frost
accumulates on out-
door unit (expansion
valve is closed).
Operation mode
Cooling mode is acti-
judgment
vated even if room
temperature is low.
Operation not
Normal operation.
affected
Rating control
Defrosting operation
Defrosting
is activated unneces-
sarily.
Expansion valve
Compressor oper-
control
ates, but room does
not become cool
(expansion valve is
open).
Expansion valve
Compressor oper-
control
ates, but room does
not become warm
(expansion valve is
open).
Expansion valve
Frost accumulates on
control
indoor unit evapora-
tor and room does
not become cool
(expansion valve is
closed).
Operation not
Normal operation.
affected
Short-circuit
Compressor high
temperature error
indication.
Outdoor unit ther-
mistor short-circuit
error indication.
Outdoor unit ther-
mistor short-circuit
error indication.
Outdoor unit ther-
mistor short-circuit
error indication.
Outdoor unit ther-
mistor short-circuit
error indication.
Outdoor unit ther-
mistor short-circuit
error indication.
Outdoor unit ther-
mistor short-circuit
error indication.
Outdoor unit ther-
mistor short-circuit
error indication.
Outdoor unit ther-
mistor short-circuit
error indication.
Outdoor unit ther-
mistor short-circuit
error indication.
3 – 4
When resistance
Open-circuit
is high (tempera-
ture judged lower
than actual)
Layer short-circuit
Outdoor unit ther-
or open-circuit may
mistor open-cir-
result in compres-
cuit error
sor in normal opera-
indication.
tion.
Normal operation.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Defrosting opera-
Outdoor unit ther-
tion is activated
mistor open-cir-
unnecessarily, and
cuit error
room does not
indication.
become warm
(expansion valve is
open).
Heating mode is
Outdoor unit ther-
activated even if
mistor open-cir-
room temperature is
cuit error
high.
indication.
Normal operation.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.
Defrosting opera-
Outdoor unit ther-
tion is not acti-
mistor open-cir-
vated, and frost
cuit error
accumulates on
indication.
outdoor unit.
Frost accumulates
Outdoor unit ther-
on evaporator inlet
mistor open-cir-
section, and room
cuit error
does not become
indication.
cool (expansion
valve is closed).
Frost accumulates
Outdoor unit ther-
on expansion valve
mistor open-cir-
outlet section, and
cuit error
room does not
indication.
become warm
(expansion valve is
closed).
Compressor oper-
Outdoor unit ther-
ates, but room does
mistor open-cir-
not become cool
cuit error
(expansion valve is
indication.
open).
Normal operation.
Outdoor unit ther-
mistor open-cir-
cuit error
indication.