Page 1
AY-XP9FR -N AY-XP12FR-N SPLIT TYPE ROOM AIR CONDITIONER OPERATION MANUAL • Uses ozone layer friendly refrigerant R410A. INDOOR UNIT OUTDOOR UNIT AE- X9FR-N AY- XP9FR-N AE- X12FR-N AY- XP12FR-N *Plasmacluster is a trademark of SHARP Corporation.
Page 2
A. Information on Disposal for Users (private households) 1. In the European Union Attention: If you want to dispose of this equipment, please do not use the ordinary dust bin! Used electrical and electronic equipment must be treated separately and in accordance with legislation that requires proper treatment, recovery and recycling of Attention: Your product is used electrical and electronic equipment.
Page 4
IMPORTANT SAFETY INSTRUCIONS CAUTIONS FOR USE Open a window or door periodically to ventilate the room, especially when using gas appliances. Insufficient ventilation may cause oxygen shortage. Do not operate the buttons with wet hand. It may cause electric shock. For safety, turn the circuit breaker off when not using the unit for an extended period of time.
SETTING DEODORANT DUST COLLECTION FILTER The deodorant dust collection filters are packed as accessory of this unit. During operation of the air conditioner, the filters remove dust and tobacco smoke from the air and discharges clean air. Take out the air filters. 1 Open the open panel.
USING THE REMOTE CONTROL LOADING BATTERIES Use two size-AAA (R03) batteries. Remove the remote control cover. Remote control cover Insert batteries in the compart- ment, making sure the ± and — polarities are correctly align- • The display indicates “AM 6:00”...
CAUTION • Do not allow the signal receiver window to receive strong direct sunlight, since it can adversely affect its operation. If the signal receiver window is exposed to direct sunlight, close a curtain to block the light. • Using a fluorescent lamp with a quick starter in the same room may interfere with transmission of the signal.
BASIC OPERATION Press the MODE button to select the op- eration mode. AUTO HEAT COOL Press the ON/OFF button to start opera- tion. • The red OPERATION lamp ( ) on the unit will light. Press the THERMOSTAT button to set the desired temperature.
TIPS ABOUT AUTO MODE In the AUTO mode, the temperature setting and mode are automatically selected according to the room temperature and outdoor temperature when the unit is turned on. Modes and Temperature Settings Outdoor (¡C) temp. Cool Cool Cool ( 4¡C) ( 5¡C) ( 6¡C)
ADJUSTING THE AIR FLOW DIRECTION VERTICAL AIR FLOW DIRECTION The air flow direction is automatically preset in each mode as follows for optimum comfort: COOL and DRY modes Horizontal air flow HEAT mode Diagonal air flow HOW TO ADJUST THE AIR FLOW DIRECTION Adjustment range Press the SWING button on the remote control once.
PROGRESSIVE AIRFLOW Press the PROGRESSIVE AIRFLOW button during cooling or dry operation when you do not want to feel cold air. Vertical adjustment louvres are set obliquely upward to deliver cool air to the ceiling. Press the button during heating operation. Vertical adjustment louvres are set downward to deliver the warm air down to the floor and warm you.
PLASMACLUSTER OPERATION The Plasmacluster Ion generator inside the air conditioner will release positive and negative plasmacluster ions into the room. Approximately the same numbers of positive and negative ions released into the air will reduce some airborne mold. During operation, press the PLASMACLUSTER button.
SELF CLEAN OPERATION SELF CLEAN operation will provide effect to reduce the growth mold fungus, and to dry inside of the air conditioner unit with Plasmacluster ions. This operation is accompanied by FAN or HEAT mode. Utilize the operation at seasonal change over terms. Mold fungus already grown can not be eliminated by this operation.
TIMER OPERATION NOTE: Before setting the timer, make sure the clock is properly set with the current time. TIMER OFF Press the TIMER OFF ( ) button. The TIMER OFF indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time.
TIMER ON Press the TIMER ON ( ) button. The TIMER ON indicator will blink; press the TIME ADVANCE or REVERSE buttons to set the desired time. (The time can be set in 10- minute increments.) Point the remote control at the signal receiver window on the unit and press the TIMER SET (SET/C) button.
AUXILIARY MODE Use this mode when the remote control is not available. TO TURN ON Lift the front panel of the indoor unit and press the AUX. button on the operation panel. • The red OPERATION lamp ( ) on the unit will light and the unit will start operating in the AUTO mode.
Page 19
MAINTENANCE CLEANING THE UNIT AND THE REMOTE CONTROL • Wipe them with a soft cloth. • Do not directly splash or pour water on them. We can cause electrical shock or equipment damage. • Do not use hot water, thinner, abrasive powders or strong solvents. MAINTENANCE BEFORE MAINTENANCE AFTER AIR CONDITIONER SEASON...
ADDITIONAL NOTES ON OPERATION OPERATING TEMPERATURE RANGE • The built-in protective de- INDOOR TEMP. OUTDOOR TEMP. vice may prevent the unit 32˚C D.B. 43˚C D.B. from operating when used upper limit 23˚C W.B. out of this range. COOLING 21˚C D.B. 21˚C D.B.
BEFORE CALLING FOR SERVICE The following conditions do not denote equipment malfunctions SWISHING NOISE UNIT DOES NOT OPERATE The soft, swishing noise is the sound of the refrig- The unit will not operate if it is turned on immediately erant flowing inside the unit. after it is turned off.
Page 24
Printed in Thailand TH 1 TINSEA448JBRZ 05H-...