AEX12GRN
CHAPTER 1.
AEX12GRN

SPECIFICATION

[1] SPECIFICATION
1. AY-XP12GR-N – AE-X12GR-N
ITEMS
Cooling capacity(Min.–Max.)
Heating capacity(Min.– Max.)
Moisture removal(at cooling)
Electrical data
Phase
Rated frequency
Rated voltage
Rated current ✩
Cool
(Min - Max.)
Heat
Rated input ✩
Cool
(Min - Max.)
Heat
Power factor ✩
Cool
Heat
Compressor
Type
Model
Oil charge
Refrigerant system
Evaporator
Condenser
Control
Refrigerant (R410A) 1050g
De-lce system
Noise level
High
(at cooling/heating)
Low
Soft
Fan system
Drive
Air flow quantity
High
(at cooling/heating)
Low
Soft
Fan
Connections
Refrigerant coupling
Refrigerant tube size Gas, Liquid
Drain piping mm
Others
Safety device
Air filters
Net dimensions
Width
Height
Depth
Net weight
NOTE: The condition of star"✩" marked item are 'ISO5151' : 1994(E), contition T1.
MODEL
INDOOR UNIT
AY-XP12GR-N
kW
3.5 (0.9 - 4.0)
kW
4.6 (0.9 - 6.5)
Liters/h
1.1
Single
Hz
50
V
220–240
A
4.2 ( 0.8 –5.7 )
A
5.3 ( 0.8 –7.8 )
W
875 (150–1250 )
W
1150 ( 160–1700 )
%
95–87
%
99–90
Hermetically sealed rotary type
DA111A1F22F
450mL Ester oil VG74
Louver Fin and Grooved tube type
Corrugate Fin and Grooved tube type
Expansion valve
Micro computer controled reversed systems
dB(A)
40/44
dB(A)
38/38
dB(A)
27/34
Direct drive
m3/min.
10.5/12.9
m3/min.
9.5/10.3
m3/min.
5.9/8.7
Cross flow fan
Flare type
1/2", 1/4"
O.D φ18
Compressor: Thermal protector
Fan motors: Thermal fuse
Fuse, Micro computer control
Polypropylene net (Washable)
mm
790
mm
278
mm
198
kg
10
Service Manual
OUTDOOR UNIT
AE-X12GR-N
47/49
32/30
Propeller fan
780
540
265
39
1 – 1

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ay-xp12gr-n