Appendix A: Alarm I/O Connector - Honeywell HICC-P-3100IRV User Manual

H.264 high profile 3m multi-profile ir vari-focal bullet network camera
Table of Contents

Advertisement

Network Camera User's Guide

Appendix A: Alarm I/O Connector

Some features of the Camera can be activated by the external sensor that senses
physical changes in the area Camera is monitoring. These changes can include intrusion
detection or certain physical change in the monitored area. For examples, the external
sensor can be a door switch or an infrared motion detector. These devices are customer
provided, and are available from dealers who carry surveillance and security products.
Electrically, they must be able to provide a momentary contact closure.
This Camera provides wires for general I/O terminal and RS485 interface as below:
Cable for I/O connectors:
Name
Number
12VDC
1
DI
2
GND
3
DO
4
485+
5
485-
6
User can refer to the schematic below to make a proper connection between I/O
connector and external sensor and output device.
Function
DC 12V (50mA maximum)
Digital signal input
GND
Digital signal output
RS485 data +
RS485 data -