Specifications; Ventilation Clearances - Follett 12CI400A-LI Installation, Operation And Service Manual

Symphony 12 series ice and water dispensers
Table of Contents

Advertisement

Specifications

16"
(407 mm)
Front View
Electrical
§ 115 V, 60 Hz, 1 phase, 13.0A
§ Connect to a dedicated 20A circuit, fuse or breaker.
Ambient
Air temp
Water temp
Water pressure
Plumbing
Dispenser drain
Water inlet
Note: Water shut-off recommended within 10 ft. (3m) of dispenser. Drain to be hard-piped and insulated. Maintain
at least 1/4" per foot (20mm per 1m) run of slope.

Ventilation clearances

§ 6" (153mm) on right side of dispenser, 6" (153mm) at top for ventilation and 12" (305mm) at top recommended
for service.
Note: Do not block right side air intake or top air exhaust.
Dry weight
§ 175 lbs. (79.4kg)
4
22.625"
(575 mm)
4"
(102 mm)
23.5"
(597 mm)
Side View
100 F/38 C Max.
90 F/32 C Max.
70 P.S.I./5Bar Max.
32"
(826 mm)
intake
18"
(458 mm)
50 F/10 C Min. (Best performance below 27 C/80 F)
40 F/4 C Min. (Best performance below 21 C/70 F)
10 P.S.I./0.7 Bar Min.
12CI400A
3/4" FPT
3/8" FPT
air exhaust
3/4" FPT drain
3/8" FPT
water inlet
air
power cord
Rear View
12HI400A
3/4" FPT
3/8" FPT
12CI400A • 12HI400A