Example of a user configuration file
# This is a comment
TIMESTAMP=3D2C4E48
FILETYPE=UDB
FILEFORMAT=01
00|00010048|Benutzer_mit_allen_Rechten|C~WB1"
01|00000040|Status_CP|UX3MUppLjRzn*R
02|00010000|FTP_Zugriff|W9vQ}G cfH
03|00000000||
04|00000000||
05|00000000||
06|00000000||
07|00000000||
END
# End of File
Note
− Commentary is added to the file with the # character.
− A blank user entry is rejected in the .udb file as follows: 0x|00000000|||
(whereby x stands for the running user number)
− The last character of a line is a \n.
− All ASCII characters between 0x21
name and password if they are acceptable to the communication partners
involved.
− Blank lines are not permitted.
Caution
When you change the .udb file manually, be sure to use a unique user name. Also
adhere to the specified lengths for the user names and the passwords. The maxi-
mum number of users may not be exceeded.
CP 243-1 IT
J31069-D0429-U001-A0-7618
and 0x7E
can be used for the user
HEX
HEX
Configuration