Converting To Another Gas Type - Frymaster GF40 Series Installation & Operation Manual

Hide thumbs Also See for GF40 Series:
Table of Contents

Advertisement

3. Close the fryer drain valve and fill the frypot with water or boil-out solution to the bottom OIL-
LEVEL line at the rear of the frypot. Light the fryer and perform the boil-out procedures that are
described in the "Start-Up Procedure" and "Boiling Out the Frypot" topics found in Chapter 3.
"Dry-firing" your unit will cause damage to the frypot. Always ensure that melted
shortening, cooking oil, or water is in the frypot before firing your unit.
In the event of a burn-back, where the flame burns back to the jet, immediately turn
the gas supply off at the control valve on the panel. After ensuring the flame is
extinguished, wait for I minute and re-light the appliance in the normal manner.
Should the appliance again burn back, close the control valve and call a service
technician. Do not use the appliance again until the service technician has declared
that it is safe to do so.
4. The burner manifold pressure be checked at this time by the local gas company or an authorized
service agent. Refer to "Check Burner Manifold Pressure" in Section 4.3 of this manual for the
proper procedure.
5. Check the thermostat calibration in accordance with the instructions in Section 4.3 of this
manual.
2.5

Converting to Another Gas Type

This appliance was configured at the factory for a specific type of gas. Converting
from one type of gas to another requires the installation of specific gas-conversion
components.
Switching to a different type of gas without installing the proper conversion
components may result in fire or explosion. NEVER ATTACH THIS APPLIANCE TO A
GAS SUPPLY FOR WHICH IT IS NOT CONFIGURED!
Conversion of this appliance from one type of gas to another should only be
performed by qualified, licensed, and authorized installation or service personnel, as
defined in Section 1.5 of this manual.
Your fryer is configured at the factory for either natural gas or Propane (LP) gas. If you desire to
switch from one type of gas to another, a Factory Authorized Servicer technician must install a
gas conversion kit.
Call Frymaster Service (1-800-551-8633) to determine the conversion kit appropriate for your
configuration and altitude. Contact your local FAS to order the kit and arrange for installation.