Options Adjustments
Item
Effect
Slot Power
V.Installation
Off
On
Rotate
Off
On
Serial Slot
Select
Normalization
When both main unit buttons and remote control are disabled due to the "Button lock", "Remocon User level" or "Remote
ID" adjustments, set all the values "Off" so that all the buttons are enabled again.
Press the
button on main unit together with
"SHIPPING" menu is displayed and the lock is released when it disappears.
42
Off
Auto
On
Off:
Power is not transmitted to the slot power.
Auto: Power is transmitted to the slot power only when main power is on.
On:
Power is transmitted to the slot power when main power is on or in the standby state.
Note: In some cases, power is transmitted to the slot power when main power is on or in the standby
state regardless of the slot power setting.
Off:
Sets fan to the horizontal installation mode.
On:
Sets fan to the vertical installation mode.
Notes:
• This functions when display is turned on.
• This mode is available for TH-42PH10UK, TH-50PH10UK and TH-58PH10UK.
• Turn up the power switch for the upward direction when you set Display vertically.
Off:
Does not rotate the image.
On:
Rotates the image 180 degrees.
Slot1
Slot2
Slot3
Selects the slot which communicates serial.
Notes:
• The setting of an external command can be set only from the fi xed serial terminal (see page 11)
• Slot3 cannot be selected on TH-37PH10UK.
button on the remote control and hold for more than 5 seconds. The
Options
Slot power
V. lnstallation
Rotate
Serial Slot Select
Adjustments
3/3
Off
Off
Off
Slot1

Advertisement