Download Print this page

HP ProLiant DL560 Quickspecs page 7

Hide thumbs Also See for ProLiant DL560:

Advertisement

QuickSpecs
Standard Features
Intelligent Manageability Integrated Lights-Out (iLO) Standard Management
Intelligent Manageability
Intelligent Manageability
Intelligent Manageability
Availability
Availability
Availability
Availability
Virtual Text Remote Console
Virtual Power Button Control
Dedicated LAN Connectivity
Automatic IP Configuration via DHCP/DNS/WINS
Industry Standard 128-bit Secure Sockets Layer (SSL) Security
IML and iLO Event Logging
Support for 12 user accounts with customizable access privileges
Integrated Lights-Out (iLO) Advanced Pack (supports Advanced features such as Graphical Remote
Console and Virtual Floppy - available as a separate option)
Automatic Server Recovery-2 (ASR-2)
HP Systems Insight Manager
Redundant ROM
Remote Flash ROM
ROM-Based Setup Utility (RBSU)
Integrated Management Log (IML)
Hot Spare Boot
NOTE:
NOTE: Upon the event of a failed processor or VRM in a multi-processing environment, the system will
NOTE:
NOTE:
automatically reboot and use the remaining good processor(s).
Dynamic sector repairing and drive parameter tracking (with Smart Array controllers)
Redundant/adaptive load balancing NIC Support
Standard Advanced ECC functionality detects and corrects single bit and specific multi-bit memory
errors (4bit and 8bit) while using industry standard registered DIMMS. Functionality is embedded
in the chipset design.
HP Advanced Memory Protection Technology – delivers unsurpassed memory protection and
server availability:
Online Spare Memory:
Offers a higher level of memory protection than Advanced ECC alone. If the number of
single-bit correctable errors on a bank exceeds the pre-defined error threshold, that bank
will fail over to the online spare bank without intervention or server interruption. The failed
memory can then be replaced at the user's convenience during a scheduled maintenance
window.
NOTE:
NOTE: All HP Advanced Memory Protection modes are user configurable through the ROM-Based
NOTE:
NOTE:
Setup Utility (RBSU) and viewable through Insight Manager 7 and the Integrated Management Log
(IML.).
Smart Array 5i Plus Controller with standard Battery Backed Write Cache (BBWC) Enabler
provides transportable data protection and increases overall controller performance. Up to 64MB
Battery Backed Write Cache protection available on 2P HP ProLiant DL560 models (BBWC
Enabler is optional on 1P model).
Redundant Cooling Zones across major server subsystems (Memory, I/O, CPU) provide 7x24
cooling. Each zone is independent of each other and is able to support N+1 redundancy, as
indicated below.
This zone configuration enables the server to withstand up to three fan failures, provided that they are
not within the same zone. Each fan is hot plug redundant and individually removable.
Up to two Hot Plug Ultra3 Drive Bays
Simplex SCSI Backplane
Dual Hot Plug Redundant Power Supplies (standard on 2P Models, one ships standard on 1P
Models)
DA - 11595
Worldwide — Version 46 — December 16, 2005
HP ProLiant DL560
HP ProLiant DL560
HP ProLiant DL560
HP ProLiant DL560
Page 7

Advertisement

loading