Chapter 8
[1]
8.9.6 Drum Cleaner Unit
8.9.6.1 Construction
/ iR85+ / iR8070
Cleaning blade
Separation claw
8.9.6.2 Construction
iR105i/iR105+ / iR9070
Cleaning blade
Blade vibration unit
8-44
[3]
[2]
F-8-74
0007-2386
F-8-75
0007-2692
Separation claw
F-8-76
8.9.6.3 Removing the Cleaning Blade
/ iR85+ / iR8070
1) Open the front cover.
2) Slide out the process unit.
3) Remove the screw [1], and detach the reciprocating arm [2].
[1]
4) Disconnect the connector [3], and remove the five screws [4]; then,
while pushing it toward the rear, detach the cleaning blade together
with the mounting plate [5].
[3]
5) Remove the E-ring [6], and detach the pressure plate [7]; then, detach
the cleaning blade assembly [8].
[8]
6) Remove the five screws [9], and detach the blade retaining plate [10];
then, detach the cleaning blade [11].
0007-2390
[2]
F-8-77
[4]
[5]
F-8-78
[7]
[6]
F-8-79