Parts Listing - IBM DR550 Problem Determination And Service Manual

Table of Contents

Advertisement

Parts listing

Figure 8 on page 49 and the following table provide a parts listing for the DR550
Storage Controller.
48
DR550 Version 4.5 Problem Determination and Service Guide
Table 7. Symptom-to-FRU index (continued)
Problem
indicator
Component
Unable to access
Drives and
drives.
fibre-channel
loop
Random errors.
Subsystem
Hard disk drive
Several CRUs
not visible in
RAID
management
software.
Possible cause
Possible solutions
Incorrect enclosure
Ensure that the fibre-channel
speed settings
optical cables are undamaged
and properly connected. Check
the enclosure speed settings.
Note: Change the enclosure
speed switch position only when
your storage subsystem is
powered off.
RAID controller
Replace one or both RAID
failure
controllers. Contact an IBM
technical support representative.
Drive or drives
Replace failed drive or drives.
failed
Midplane failure
Have the midplane replaced.
Contact an IBM technical
support representative.
Drive or drives
Replace failed drive or drives.
failed
FC cable failed
Replace FC cable.
SFP failed
Replace SFP.
RAID controller
Replace RAID controller.
failure
Unsupported
Verify that the attached storage
storage expansion
expansion enclosures are
enclosure connected
supported. In this release, the
DR550 Storage Controller only
supports DR550 Expansion
Drawers (EXP420) not EXP810s.
Drive CRU has
Replace the drive CRU.
interface problem
with the ESM or
controller.
Incorrect firmware
Verify that the DR550 Storage
version
Controller has the correct
firmware version. See DS4200
Installation, User's and
Maintenance Guide.
Midplane failure
Have the midplane replaced.
Contact an IBM technical
support representative.

Advertisement

Table of Contents
loading

Table of Contents