Specifications Of Electrical Parts - Toshiba RAS-B16N3KV2-E1 Service Manual

Indoor unit/outdoor unit
Hide thumbs Also See for RAS-B16N3KV2-E1:
Table of Contents

Advertisement

6. SPECIFICATIONS OF ELECTRICAL PARTS

6-1. Indoor Unit
No.
Parts name
Fan motor
(RAS-B10N3KV2-E1, RAS-B13N3KV2-E1)
1
(RAS-B16N3KV2-E1)
2
Room temp. sensor (TA-sensor)
3
Heat exchanger temp. sensor (TC-sensor)
4
Louver motor
6-2. Outdoor Unit
No.
Parts name
1
Reactor
2
Outdoor fan motor
3
Suction temp. sensor (TS sensor)
4
Discharge temp. sensor (TD sensor)
5
Outside air temp. sensor (TO sensor)
6
Heat exchanger temp. sensor (TE sensor)
7
Terminal block (5P)
8
Compressor
9
Coil for PMV
10
Coil for 4-way valve
Type
RPG-240-25A
MF-340-30-3
( - )
( - )
24BYJ48-HTP
Type
CH-69
10, 13k
16k
CH-57
ICF-140-43-4R
(Inverter attached)
(Inverter attached)
(Inverter attached)
(Inverter attached)
JX0-5B
ASM89D16UEZ
10, 13k
16k
DA131S1B-31FZ
CAM-MD12TCTH-5
10, 13k
SQA2522G-000352
16k
STF-H01AJ1872A1
21
FILE NO. SVM-15006
Specifications
AC 240V, 20W
DC 340V, 30W
10kΩ at 25°C
10kΩ at 25°C
Output (Rated) 1W, 16 poles, DC12V
Specifications
L = 19mH, 10A
L = 10mH, 16A
DC140V, 43W
10kΩ (25°C)
62kΩ (20°C)
10kΩ (25°C)
10kΩ (25°C)
20A, AC250V
3-phases 4-poles 750W
3-phases 4-poles 1100W
DC12V
AC220-240V
AC220-240V

Hide quick links: