Function - Buderus 500 - 28/C Servicing Manual

Gas wall hung boiler condensing
Hide thumbs Also See for 500 - 28/C:
Table of Contents

Advertisement

4

Function

4
Function
box 15
Boiler Functions
Turn the mains switch to "ON".
step 1
Turn the operating switch on the DBA control panel of the boiler to position "1" (ON) – see also box 11.
step 2
Is a 3-way valve fitted?
step 3
Is the 3-way valve set to "hot water mode"?
step 4
The Buderus 24V AC external 3-way valve is turned to "heating mode" in 7.5 seconds, while an internal 3-way
step 5
valve is turned to "heating mode" in 2 seconds.
,00{
The display on the DBA control panel of the boiler is checked (maximum of one second).
step 6
[24]
Current CH flow temperature, in °C. See also box 20.
step 7
C [0u]
The boiler begins to warm up. Start of pre purge phase.
step 8
The fan runs for 15 seconds at about 60 % of maximum speed.
Has the pre purge been completed correctly?
step 9
step 10 Deal with fault. The error code, which is now displayed, can be found in box 20. Deal with the fault.
C [0h]
Operating code. See also box 20. The boiler is ready for operation.
step 11
No current heat requirement.
step 12 Start of pump over-run time via the heating system.
The pump over-run time:
– via the heating system, factory-adjusted to 5 minutes;
– via the external reservoir, set to 30-40 seconds;
– via the plate heat exchanger (ECO), set to 30-40 seconds;
– via the plate heat exchanger (warm start), set to 30 seconds;
– after service mode, 1 minute.
step 13 Has the pump over-run time expired?
step 14 Is the boiler set to warm start for hot water and/or is an external storage-type water heater connected?
step 15 Is the plate heat exchanger triggered and/or is the temperature in the external storage-type water heater at least
5 °C below the temperature set at the DBA control panel?
step 16 Is there a current heat requirement from the (room) temperature controller?
step 17 Is the current CH flow temperature lower than 7 °C (frost protection)?
step 18 The pump stops.
step 19 Has the pump been out of use for more than 24 hours?
step 20 Is the plate heat exchanger triggered and/or is the temperature in the external storage-type water heater at least
5 °C below the temperature set at the DBA control panel?
step 21 Is there a current heat requirement from the (room) temperature controller?
We reserve the right to make technical modifications
14
Start phase
Servicing manual Gas condensing boiler Buderus 500-24/S, 500-24/C and 500-28/C • Issued 02/2006
Checking phase
Operating phase
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Buderus Ltd. • http://www.buderus-domestic.co.uk
step 4
step 6
step 5
step 6
step 11
step 10
step 18
step 14
step 15
step 16
step 28
step 16
step 46
step 19
step 62
step 18
step 23
step 20
step 28
step 21
step 46
step 22