Buderus 500 - 28/C Servicing Manual page 28

Gas wall hung boiler condensing
Hide thumbs Also See for 500 - 28/C:
Table of Contents

Advertisement

6
Diagnosis
box 26
Have a hot water tap or taps been opened briefly and consectutively on several occasions?
step 8
Inform the user that the fault has been caused by opening hot taps on many brief, consecutive occasions.
step 9
Check the electrical resistance of the DHW temperature sensor, see box 104.
step 10
Is the electrical resistance of the DHW temperature sensor in order?
step 11
Replace the DHW temperature sensor.
step 12
box 27
C [0y]
C [2f]
C [2p]
[4a]
[4e]
Are the servicing valves open?
step 1
Open the servicing valves, see box 53.
step 2
Is the pressure in the heating system at least 1 bar?
step 3
Fill and vent the heating system, see box 52.
step 4
Are enough thermostatic valves open on the radiators, convectors, etc?
step 5
Open more thermostatic valves on the radiators, convectors, etc.
step 6
Check the flow NTC sensor and safety sensor, see box 104.
step 7
Are the flow NTC sensor and safety sensor in order?
step 8
Replace the flow NTC sensor or safety sensor, see box 116.
step 9
Check the cable between the flow NTC sensor or safety sensor for short circuits, see box 112.
step 10
Check the pump, see box 89 to 100.
step 11
Is the pump working correctly?
step 12
Replace the pump, see box 101.
step 13
Check to ensure that the internal by-pass valve in the boiler or the external overflow valve in the heating
step 14
system are working correctly. Possible to adjust external overflow valve to max. 25 kPa (if fitted).
Is the by-pass valve working correctly?
step 15
We reserve the right to make technical modifications
28
The flow NTC sensor or safety sensor has detected that the current CH flow
temperature is higher than 95 °C.
Blocking boiler-fault code
The flow NTC sensor and safety sensor have not, after burner startup, detected any
temperature increase in the heating system water, or the temperature difference
between the flow NTC sensor and safety sensor is excessive.
Blocking boiler-fault code
The flow NTC sensor has detected a temperature increase in the heating system
water of more than 5 °C/sec.
Blocking boiler-fault code
The flow NTC sensor and safety sensor have detected a CH flow temperature of over
105 °C.
Locking boiler-fault code
Short circuit between flow NTC sensor or safety sensor.
Locking boiler-fault code
Servicing manual Gas condensing boiler Buderus 500-24/S, 500-24/C and 500-28/C • Issued 02/2006
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Yes:
No:
Buderus Ltd. • http://www.buderus-domestic.co.uk
step 9
box 15
box 42
box 41
step 12
step 3
step 2
step 5
step 4
step 7
step 6
box 42
step 10
step 9
box 42
step 14
step 13
box 41
step 14