Daikin FVKS25BVMB Service Manual page 147

Inverter pair floor standing type b-series
Hide thumbs Also See for FVKS25BVMB:
Table of Contents

Advertisement

Indoor Unit
Step
4
Loosen the six screws
(three for the upper
side motor and three
for the bottom one) to
remove the fan motors.
Remove the motors
5
and cross flow fans.
6
To remove the casing,
loosen the four screws
at front side and the
other four screws at
rear side.
138
Procedure
SiBE06-514A
Points
Short lead wire: for the upper
fan motor
Long lead wire: for the
bottom fan motor
Mounting screw M4 × 16
Loosen the fixing screw to
separate the fan and motor.
Casing mounting screw
Front: M4 × 16
Rear: M4 × 14
Condition : Casing
Protruded : Not to be removed
Semi-sink : To be removed
Sink : Not to be removed
Removal Procedure