Figure 7 RJ-45 (Female) to DB-9 (Male) Modular Adapter Conversion
RJ-45 Female
Direction
Power Connection
The OAW-AP120 series AP has a single 5V DC power jack socket to support powering through an AC-to-
DC mains electric power adapter.
Connecting a Security Cable
To provide added security for the AP, you can attach a security cable to the back of the unit (see
8).
Figure 8 Security Lock Connection
Verifying Post-Installation Connectivity
The integrated LEDs on the AP can be used at this point to verify that the AP is receiving power and
initializing successfully (see
details on verifying post-installation network connectivity.
Table 3 OAW-AP120 Series LED Meanings
LED
PWR
ENET 0
(100/1000 Mbps)
ENET 1
(100/1000 Mbps)
11A/N
8
Pin-Out
1
2
3
TxD
4
5
GND
6
RxD
7
8
Input
Output
Table
Color/State
Green Steady
Green flashing
Green/Amber off
Green on
Amber on
Green/amber blinking
Green/Amber off
Green on
Amber on
Green/amber blinking
Amber on
Green on
Internal
Connections
RJ-45
DB-9
3
2
TxD
4
5
5
GND
6
3
RxD
3). Refer to the Alcatel-Lucent AOS-W Quick Start Guide for further
Meaning
Power on, device ready
System initializing
No link
1000 Mbps link
10/100 Mbps link
Data activity
No Link
1000 Mbps link
10/100 Mbps link
Data activity
Wireless link is legacy 11a.
Wireless link is 11n 5Ghz band.
Alcatel-Lucent OAW-AP120 Series Indoor Access Point
DB-9 Male
Pin-Out
5
Ground
9
4
8
3
RxD
7
2
TxD
6
1
Direction
Input
Output
Figure
| Installation Guide