Quiet Operation; Mode) - Panasonic CS-HE9DKE Service Manual

Panasonic air conditioner user manual
Hide thumbs Also See for CS-HE9DKE:
Table of Contents

Advertisement

CS-HE9DKE CU-HE9DKE / CS-HE12DKE CU-HE12DKE
9.5.
Quiet operation (Cooling Mode / Cooling area of Dry Mode)
A. Purpose
To provide quiet cooling operation at limited fan speed which lower than Manual Low Fan Speed. (See 9.6 Fan Motor Operation
table.)
It improves the operation noise approximately 3dB compared to Manual Low Fan Speed.
B. Control condition
a. Quiet operation start condition
When QUIET button at remote control is pressed.
(QUIET is approved on LED at remote control.)
b. Quiet operation stop condition
One of the following conditions is satisfied, QUIET operation is to be concealed.
1. Repressing QUIET button during quiet operation.
2. Pressing POWERFUL button.
3. Pressing FAN SPEED button, the operation is to be shifted to the selected fan speed.
4. Changing the operation mode to IONIZER only operation.
5. Stopping the operation by OFF/ON button and/or OFF Timer.
9.5.1.
Quiet operation under Dry operation (Dry area at Dry Mode)
Automatic Fan Speed (Dry operation)
Manual Fan Speed (Dry operation)