Stapler diverter plunger assembly removal
1
Remove the finisher left cover. See
2
Remove the three screws (A) from the main motor bracket.
Note: Removing the main motor bracket will not be required. Just move it out of the way to make it easier to
release the diverter motor bracket.
3
Remove the two screws (B) from the diverter motor bracket.
Note: Removing the diverter motor bracket will not be required. Just move it out of the way to access the parts
underneath it.
"Staple, hole punch left cover removal" on page
Repair information