Alcatel-Lucent OmniSwitch 6860 Troubleshooting Manual page 46

Hide thumbs Also See for OmniSwitch 6860:
Table of Contents

Advertisement

OmniSwitch OS6860/OS6900/OS10K Troubleshooting Guide
AOS Release 7.X and 8.X
For STP mode 1x1 please use (vid,1) as the argument
SHASTA #-> debug $(pidof stpNi) "call stpni_printStats(1,1)"
[Thread debugging using libthread_db enabled]
Using host libthread_db library "/lib/libthread_db.so.1".
0xb6a31cbc in epoll_wait () from /lib/libc.so.6
--------------------------------------------------------------------------------------------
|
RX
PORT| Bpdu RBpdu MBpdu Flg80 Flg01
--------------------------------------------------------------------------------------------
x00:
0
124
0
x02:
0
124
0
--------------------------------------------------------------------------------------------
$1 = 1
For STP and MSTP mode flat please use (0,0) as the argument
SHASTA #-> debug $(pidof stpNi) "call stpni_printStats(0,0)"
[Thread debugging using libthread_db enabled]
Using host libthread_db library "/lib/libthread_db.so.1".
0xb6a31cbc in epoll_wait () from /lib/libc.so.6
--------------------------------------------------------------------------------------------
|
RX
PORT| Bpdu RBpdu MBpdu Flg80 Flg01
--------------------------------------------------------------------------------------------
x00:
0
289
0
x02:
0
289
0
--------------------------------------------------------------------------------------------
$1 = 1
For MSTI instance 1 please use (1,0) as the argument. { (instance,0) 0 represents the flat mode }
SHASTA #-> debug $(pidof stpNi) "call stpni_printStats(1,0)"
[Thread debugging using libthread_db enabled]
Using host libthread_db library "/lib/libthread_db.so.1".
0xb6a31cbc in epoll_wait () from /lib/libc.so.6
--------------------------------------------------------------------------------------------
|
RX
PORT| Bpdu RBpdu MBpdu Flg80 Flg01
--------------------------------------------------------------------------------------------
x00:
0
289
0
x02:
0
289
0
--------------------------------------------------------------------------------------------
$1 = 1
Column description:
RX - All the BPDU received by the swith
Bpdu - 802.1d BPDUs
RBpdu - 802.1w BPDUs
Flg80 - BPDUs with flag 80 set (Topology Change Acknowledgement)
Flg01 - BPDUs with flag 01 set (Topology Change)
TX: All the BPDU sent by the swith
Bpdu - 802.1d BPDUs
RBpd - 802.1w BPDUs
Flg80 - BPDUs with flag 80 set (Topology Change Acknowledgement)
Flg01 - BPDUs with flag 01 set (Topology Change)
Alcatel-Lucent
|
TCN | Bpdu RBpdu MBpdu Flg80 Flg01
0
4
0
0
0
4
0
0
|
TCN | Bpdu RBpdu MBpdu Flg80 Flg01
0
6
0
0
0
6
0
0
|
TCN | Bpdu RBpdu MBpdu Flg80 Flg01
0
6
0
0
0
6
0
0
TX
9
0
0
4
5
0
0
2
TX
11
0
0
6
7
0
0
3
TX
11
0
0
6
7
0
0
3
Part No.032996-00 Rev.A
January 2015
|
AGGR BPDU
TCN |
Rx
Tx
0
0
0
0
0
0
|
AGGR BPDU
TCN |
Rx
Tx
0
0
0
0
0
0
|
AGGR BPDU
TCN |
Rx
Tx
0
0
0
0
0
0
Page 46 of 148

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Omniswitch 6900

Table of Contents