Appendix E FRU Replacement
This section details replacement information for various Intel
replacement parts, contact Intel or an approved reseller.
Note:
If it is part of a standard operating procedure, add replacement identification tags to both
the rack and the FRU hardware to ensure that the warranty is transferred to the
replacement part(s).
Note:
If the FRU being replaced is in an active chassis (that is, hot swapping), please replace
the FRU within 2 minutes to maintain thermal integrity.
E.1

Intel 12200

Note:
For an externally-managed 12200, refer to the Intel
User Guide for update information.
E.1.1

Chassis Replacement

FRU part numbers:
• Standard chassis: 12200BS01
• Reversed airflow/AC power inlets: 12200BS02
E.1.1.1
Removal Procedures
1. Power down the switch by unplugging AC power.
2. Remove all applicable IB, Ethernet and serial cables. Set these aside for
3. Remove the switch from the rack. Keep all rail hardware installed in the rack.
4. Remove the hat rails from the switch. Set these aside for reinstalling the
E.1.1.2
Replacement Procedures
1. Install the hat rails to the switch.
2. Rack mount the switch in the existing rails on the rack.
3. Connect Ethernet and serial cables (managed 12200 only).
4. Connect AC power.
5. If applicable, change the switch, gateway and subnet mask addresses to a new
6. Cable all applicable IB ports.
E.1.2

Management Card Installation or Replacement

FRU part number:
• 12000MM01 installed in 12200BS01
G91928
reinstalling the replacement switch.
replacement switch.
network address.
®
12000 FRUs. For
®
True Scale Fabric Suite FastFabric