Circulation Pump - Navien NCB-24LSWE Service Manual

Condensing combi boiler
Hide thumbs Also See for NCB-24LSWE:
Table of Contents

Advertisement

4.9.14 Circulation Pump

Item
Function
Fault
Symptoms
Error codes
Diagnostics
Testing/inspection
information
Version 1.0
1. Provides internal or external water circulation.
2. Internal circulation minimises the effects of temperature fluctuations. External circulation
quickly delivers hot water to taps and results in water conservation.
Unable to detect or measure water flow.
1. Water inside the boiler system freezes.
2. Water temperature fluctuations when the boiler is set to internal recirculation.
3. Hot water takes a long time to be available at taps when the boiler is set to external
recirculation.
-
1. Visual inspection: Check the circulation pump connection wire.
2. Check the water filter for obstructions.
3. Voltage test: Test the voltage meets the specifications shown below.
YELLOW-WHITE
 ON: AC 230 V
 OFF: 0 V
Description
NCB Service Manual 73

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ncb-28lsweNcb-34lsweNcb-40lswe

Table of Contents