Troubleshooting Guide By Symptom; Noise - Navien NCB-24LSWE Service Manual

Condensing combi boiler
Hide thumbs Also See for NCB-24LSWE:
Table of Contents

Advertisement

5.3 Troubleshooting guide by symptom

5.3.1 Noise

Error type
Defective
installation
Vibration noise
Fan vibration noise
Defective flow
Regular noise
Malfunction of the
3-way valve
Gas and air
differential
Noise at ignition
pressure error
(Pop, Beep,
Explosive ignition)
Boiling noise
Whirring
Noise during
combustion
Low gas pressure
(whirring)
Noise during
combustion
Version 1.0
Cause
Incorrect mounting to the wall or in an improper location.
 Check for improper installation and reinstall the unit if necessary.
Vibration caused due to defective blower.
 Check the blower. If vibration is significant, replace the fan.
 If intermittent noise occurs during operation, check the fan for debris.
 If vibration noise occurs during operation of the product, and stops when the
case lid is removed, check the fan.
Rotating noise due to debris caught in the flow sensor.
sensor
Noise due to repeated operation of the 3-way valve due to a defective PCB.
1. Offset pressure adjustment error (refer to page 21).
Adjust offset pressure with the pressure adjusting screw on the main gas
valve.
Use the Front Panel to set the unit at "MIN.1" (refer to page 55).
If noise occurs at standard value, adjust setting above/below the standard.
2. Gas supply error due to defective air pressure sensor.
3. If the same error is repeated, it is due to a defective PCB.
 How to check boiling:
 The heat exchanger is clogged partially due to scale deposits. Flush the main
heat exchanger to remove scale.
 Replace the heat exchanger if the error occurs from the start of the installation.
Exhaust gas that is recirculated into the boiler through the air inlet could produce
abnormal combustion noises.
 Check the distance between intake and exhaust (at least 12" (300mm)).
 Check the distance between flues if two or more units are installed (at least 12"
(300mm)).
 Check if there are any obstructions near the flue.
1. Noise occurs due to low gas pressure.
Check the gas supply pressure (dynamic pressure)
2. Low gas supply due to offset pressure error (refer to page 21).
Use the Front Panel to set the unit at "MIN.1" (refer to page 55).
Noise due to defective air pressure sensor.
 Replace the air pressure sensor.
 Noise due to damaged air pressure hose.
 Noise may be intermittent depending on the size of the damage.