Wiring - Empire Comfort Systems OP36FP32MN-3 Installation Instructions And Owner's Manual

Outdoor gas fireplace
Table of Contents

Advertisement

Label all wires prior to disconnection when servicing controls.
Wiring errors can cause improper and dangerous operation.
Verify proper operation after servicing.
Millivolt thermopile is self-powered. The gas valve does not
require 120 volts. Maximum length of 20 ft of 16 AWG to
conductor wires is to be used with all optional switches.
Use the two leads (Red and Green) to attach optional controls.
(OPTIONAL) REMOTE CONTROL RECEIVER
OFF ON SWITCH
OFF
ON
THERMOPILE
IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THIS UNIT MUST BE
REPLACED, IT MUST BE REPLACED WITH NO. 18, 150ºC WIRE OR ITS
EQUIVALENT
Figure 20 - Millivolt Wiring
Page 20

WIRING

(OPTIONAL) WALL SWITCH
BLACK
BLACK
CUSTOMER PROVIDED
WALL SWITCH
WHITE
GAS CONTROL
ORANGE
VALVE
HI/LO
PILOT
Solenoid
MAIN
SPARKER
BLACK
(SENSOR)
ORANGE
(IGNITOR)
RED
BLACK
Figure 21 - IP Wiring
NOTICE: Do not connect 120V to this unit.
NOTICE for IP fireplaces only: The fireplace may be operated
without the remote by connecting the brown control module wires
to a wall switch. The remote/off switch on the control module
must be in the "OFF" position.
NOTICE: For remote use, slide switch on battery box to "ON"
position.
N/A
BROWN
GREEN
(GND)
ELECTRONIC
CONTROL MODULE
AF-4000 B/P
BLACK
BROWN
RED
ORANGE
33858-1-0615