Cleaning And Service - Empire Comfort Systems OP36FP32MN-3 Installation Instructions And Owner's Manual

Outdoor gas fireplace
Table of Contents

Advertisement

Keep the control compartment, logs and burner area clean by
vacuuming or brushing the area at least once a year.
Cleaning Instructions
This fireplace is built using mostly high-grade stainless steel to
resist rust-through. In outdoor applications, all stainless steel will
develop a dull patina and, depending on the local environment
and on the materials used in the installation, may develop some
surface oxidation (rust). This does not affect the performance of
the fireplace, and does not require any action to correct. If you
prefer keeping your fireplace front looking factory-fresh, clean it
as required with stainless steel cleaner.
The logs and burner can get very hot - handle only when cool.
Always turn off gas to the fireplace before cleaning. For
relighting, refer to the lighting instructions located on the rating
plate or on pages 17 and 18.
PERIODIC CLEANING – Refer to parts diagram for location
of items discussed below.
Do not use cleaning fluid to clean logs or any part of this
fireplace.
Brush Logs with soft bristle brush or vacuum with brush
attachment.
Remove loose particles and dust from the burner areas,
controls, piezo covers and grate.
Inspect and clean burner air intake hole. Remove lint or
particles with brush. Failure to keep air intake hole clean will
result in poor combustion.
For damp or wet ignitor problems, see item 11 in the
troubleshooting section.
Page 22

CLEANING AND SERVICE

WARNING
ANNUAL CLEANING/INSPECTION – Refer to parts diagram
for location of items discussed below.
Inspect and clean burner air intake hole. Remove lint or
particles with vacuum or brush. Failure to keep air intake
hole clean will result in poor combustion.
Inspect and clean all burner ports.
Inspect ignitor for operation and accumulation of lint at air
intake ports.
Verify flame pattern and log placement for proper operation.
Verify smooth and responsive ignition of main burner.
Replace batteries annually in the remote control system on
in the IP battery backup.
Millivolt - Figure 22
Visually check the ignitor for dirt and damage as the fireplace is
installed.
In normal operation at full rate after 10 to 15 minutes, the flame
appearance should be sets of yellow flames.
NOTICE: All flames will be random by design, flame height will
go up and down.
Initial Break-in
The initial break-in operation should last 2-3 hours with the
burner at the highest setting. Any odors remaining after this initial
break-in will be slight and will disappear with continued use.
33858-1-0615

Advertisement

Table of Contents
loading

Table of Contents