Gas Supply - Empire Comfort Systems OP36FP32MN-3 Installation Instructions And Owner's Manual

Outdoor gas fireplace
Table of Contents

Advertisement

The fireplace installation must conform with local codes, or in the
absence of local codes with the National Fuel Gas Code, ANSI
Z223.1/NFPA 54; International Fuel Gas Code, Natural Gas and
Propane Installation Code, CSA B149.1; or Propane Storage and
Handling Code, B149.2, as applicable.
Check all local codes for requirements, especially for the size and
type of gas supply line required.
Recommended Gas Pipe Diameter
Pipe Length
Schedule 40 Pipe
Inside Diameter
Nat.
0-10 feet
1/2
10-40 feet
1/2
40-100 feet
1/2
100-150 feet
3/4
NOTICE: Check to confirm whether your local codes allow
copper tubing or galvanized.
NOTICE: Because some municipalities have additional local
codes, consult your local authority and installation code.
Installing a New Gas Shut-Off Valve
Each appliance must have its own manual gas shut-off valve
located in the vicinity of the unit. Where none exists, or where
its size or location is not adequate, contact your local authorized
installer for replacement or relocation.
Test for leaks. Turn fireplace off. Compounds used on threaded
joints of gas piping shall be resistant to the action of liquefied
petroleum gases. The installer must check all gas connections
for leaks. Perform all leak tests with a leak test solution or soap
solution. Rinse off all solution once testing is complete. Perform a
pressure test on all unexposed connections.
Never use an exposed flame to check for leaks. Never
pressure test with appliance connected; control valve will
sustain damage. Disconnect the appliance from piping at the
control valve inlet and cap the pipe before pressure testing.
Install a gas valve and ground joint union in the gas line upstream
of the gas control to aid in servicing. The National Fuel Gas
Code requires installing a drip line near the gas inlet. The drip
line consists of a vertical length of capped pipe installed before
the gas inlet to collect condensation and foreign particles. See
Figure 5.
33858-1-0615

GAS SUPPLY

Tubing, Type L
Outside Diameter
LP
Nat.
(Dimensions in inches)
3/8
1/2
3/8
1/2
5/8
1/2
1/2
3/4
1/2
1/2
7/8
3/4
GAS SUPPLY PLUMBING
MANUAL
SHUT-OFF VALVE
GAS SUPPLY
INLET
1/8 NPT PLUGGED
HOLE FOR
TEST GAGE
LP
The use of the following gas connectors is recommended:
— ANSI Z21.24 Appliance Connectors of Corrugated Metal
Tubing and Fittings
— ANSI Z21.45 Assembled Flexible Appliance Connectors of
Other Than All-Metal Construction
The above connectors may be used if acceptable by the authority
having jurisdiction The Commonwealth of Massachusetts
requires that a flexible appliance connector cannot exceed 3 feet.
TO CONTROL
VALVE
DRIP LEG
3" MINIMUM
Figure 5
Figure 6
Page 11