Problem solving guide
Problem
The drinking vessel
being used is
repeatedly not
recognised by the
automatic spout
adjustment.
The central spout
lowers until it touches
the top of the cup or
glass and cup
protection switch-off is
activated.
Cup protection switch-
off does not work. The
central spout lowers
until it touches the top
of the vessel and the
cleaning container or
another vessel gets
caught between the
central spout and the
drip tray.
84
Possible cause and remedy
The container is unsuitable for the cup sensing
system.
 Use cups or glasses that are suitable for automatic
spout adjustment.
There is a fault with the automatic spout adjustment.
 Switch the machine off with the On/Off  sensor.
Wait for approx. 2 minutes before switching it back
on again.
 Use another drinking vessel and prepare a drink.
 If cup protection switch-off is activated again or
the central spout lowers until it touches the top of
the cup or glass again, please contact Miele.
If the cleaning container is sitting too close to the
panel behind the central spout, or even touches it, the
rim of the container will not be properly recognised by
the automatic spout adjustment.
 Move the cleaning container forwards a little.