Siemens simovert master drive Operating Instructions Manual page 68

Types j to m dc-ac
Table of Contents

Advertisement

Technical Data
Inverter types
Rated voltage, rated frequency, rated current, rated output
Rated voltage in V
n
Input
Output
Rated frequency f
n
Input
Output:
U/f = konst
U = konst
Rated current I
n
Input
Output
DC link voltage V
dn
Rated output
Auxiliary power supply
DC 24 V (20 V - 30 V)
Auxiliary power supply
Loading Class II acc. to EN 60146-1-1
Rated current
Base load time
Overcurrent
Overcurrent time
Losses, cooling, power factor
Power factor
Converter cosϕ
U
Efficiency η
− Pulse frequency 2.5 kHz
Power loss
− Pulse frequency 2.5 kHz
Required cooling air flow
Pressure drop ∆p
Sound pressure level, dimensions, weights
Sound pressure level
Type
Width
Height
Depth
Ground
− IP00
Required current for fan (typical)
230 V / 50 Hz
230 V / 60 Hz
9-4
6SE70... 41-0UM20 41-1UM20 41-2UM20 41-4UM20 41-6UM20
V
DC 675...780 ±15 %
3 AC 0 ... Rated voltage / 1.35
Hz
0 ... 600
8 ... 300
A
1178
990
V
= Rated voltage
kVA
857...986 935...1076 1065..1225 1212..1394 1368..1574
A
AC 230 ±15%
V
A
901
s
A
1346
s
< 0.92 ind. < 0.92 ind. < 0.92 ind. < 0.92 ind. < 0.92 ind.
0.98
kW
14
3
m
/s
1.5
Pa
640
dB(A)
85
M
mm
2300
1910
580
kg
ca. 1500
A
10.4
A
13.4
1285
1464
1080
1230
5 + 3 without Options;
with Options refer to Section 6.1
983
1119
240
1469
1673
60
0.98
0.98
17
21
1.5
1.5
640
640
85
85
M
M
2300
2300
1910
1910
580
580
ca. 1500
ca. 1500
10.4
10.4
13.4
13.4
SIMOVERT MASTER DRIVES
1666
1880
1400
1580
1274
1438
1904
2149
0.98
0.98
25
28
1.7
1.7
950
950
88
88
M
M
2300
2300
1910
1910
580
580
ca. 1500
ca. 1500
26.8
26.8
40.0
40.0
Siemens AG
6SE7087-6BM70
Operating Instructions
12.96

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents