Servicing the Battery

Service Interval: Every 50 hours—Check the battery
condition.
Important: Before welding on the machine, disconnect
the negative (black) cable from the battery to prevent
damage to the electrical system.
Note: Keep the terminals and the entire battery case clean to
avoid slow discharge. To clean the battery, remove it from the
machine and wash the entire case with a solution of baking
soda and water. Rinse with clear water. Coat the battery posts
and cable connectors with Grafo 112X (skin-over) grease
(Part No. 505-47) or petroleum jelly to prevent corrosion.

Fuses

Figure 35
Unhook the latch and raise operator's console panel
36) to expose the fuses
(Figure
(Figure
37).
1. Latch
1. Fuses
41
Figure 36
2. Operator's console panel
Figure 37