Charger Indicator - Parkside PABH 18 LI A1 Operation And Safety Notes

Hide thumbs Also See for PABH 18 LI A1:
Table of Contents

Advertisement

Available languages

Available languages

10. Charger indicator

Indicator status
Red LED
Green LED
Off
Flashing
On
Off
Off
On
Flashing
Off
Flashing
Flashing
On
On
Anl_4513632.indb 18
Anl_4513632.indb 18
GB/IE
Explanations and actions
Ready for use
The charger is connected to the mains and is ready for use; there is no
battery pack in the charger.
Charging
The charger is charging the battery pack in quick charge mode.
The battery pack is fully charged (charging completed).
Action:
Take the battery pack out of the charger. Disconnect the charger from
the mains supply.
Adapted charging
The charger is in gentle charging mode. For safety reasons the charging
is performed less quickly and takes more than 1 hour. The reasons can
be:
- The battery pack has not been used for a very long time or an alrea-
dy fl at battery was further discharged (exhaustive discharge).
- The battery pack temperature is outside the ideal range (between
10° C and 45° C).
Action:
Wait for the charging to be completed; you can still continue to charge
the battery pack.
Fault
Charging is no longer possible. The battery pack is defective.
Action:
Never charge a defective battery pack. Take the battery pack out of
the charger.
Temperature fault
The battery pack is too hot (e.g. due to direct sunshine) or too cold
(below 0° C).
Action:
Remove the battery pack and keep it at room temperature
(approx. 20° C) for one day.
- 18 -
17.01.13 10:02
17.01.13 10:02