Dometic RTX1000 Operating Manual page 23

Parking cooler
Hide thumbs Also See for RTX1000:
Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1
CoolAir RTX1000, RTX2000
8.2
Control panel fault messages
The "ERROR" symbol (fig. 4 5, page 4) lights up if there is a fault with the
parking cooler. The type of error is shown on the display by the following error
codes:
Display
Description
text
The compressor does
F01
not work.
F02
F03
F04
The condensor fan 1
does not work.
F05
The condensor fan 1 is
overloaded.
F06
The condensor fan 2
does not work.
F07
The condensor fan 2 is
overloaded.
F08
The evaporator fan does
not work.
F09
The evaporator fan is
overloaded.
F10
The system cannot
F11
determine the internal
temperature.
F12
EN
Cause
Error in compressor
sensor electrical supply
(open circuit).
Error in compressor
sensor electrical supply
(short circuit).
Compressor overload
No response from the
fan.
Faulty fan speed
No response from the
fan.
Faulty fan speed
No response from the
fan.
Faulty fan speed
Error in temperature
sensor electrical supply
(open circuit).
Error in temperature
sensor electrical supply
(short circuit).
Display messages
Remedy
➤ Switch off the system.
➤ Switch it on again after
30 minutes.
➤ If the fault occurs again,
contact an authorised
workshop.