Download Print this page

Aube Technologies TH101A Owner's Manual page 2

Aube technologies thermostat owner's manual

Advertisement

PROGRAMMING
ATTENTION : The thermostat cannot be programmed if it
is not connected on the 120/240 VAC line.
1) Adjustment of time and day
Example of setting : Thursday 8:15 AM
Note: The thermostat has an automatic return. When such functions as time
recording, programs recording, etc., are not completed by pressing RET key,
the thermostat will automatically exit the mode.
2) Typical proposed programs
This thermostat can store up to six (6) programs. Four (4) programs for the
weekdays and two (2) programs for the weekend.
To practice programming use the following example.
WEEKDAY PROGRAMS (MON...FRIDAY)
PROGRAM
STARTING
NUMBER
TIME
Program 1
6:00 AM
Program 2
8:30 AM
Program 3
4:30 PM
Program 4
11:00 PM
WEEKEND PROGRAMS (SAT & SUN)
Program 1
7:00 AM
Program 2
11:00 PM
Press once on HOUR key to enter time
and day setting.
Press HOUR key a second time and hold
it until 8:00 appears on the display.
Press and hold MIN key until 8:15 appears
on display.
Press 3 times on DAY key until TH
appears on display.
Press RET to exit the time and day
adjustement mode.
TEMPERATURE
SETTING
20 °C
15 °C
20 °C
15 °C
20 °C
15 °C
3) Program ming the thermostat
4) Programming the Stanby mode temperature
Press PGM key once.
The default values or the last recorded
program 1 will be displayed.
The default values are 20 °C and 0:00
hour.
The
days
MOnday
to
FRiday
displayed showing that this program is
associated to weekdays.
Press HOUR key until 6:00 AM is
displayed.
Press t or s button until 20 °C is
displayed.
The first program is recorded.
Press PGM key again to modify weekday
programs 2, 3, 4, and weekend programs
1 and 2.
Use HOUR, MIN, t or s key to modify
programs time and setpoint.
Note: A program time left at 0:00 is
considered not effective.
To reset a program, use PGM key to
select the program, than press MODE
button.
Programming is now completed. Press
RET key or wait for "automatic return" to
exit the programming mode.
The STBY ( STANDBY ) temperature is
the desired temperature setting for a
prolonged absence.
Press MODE button while PGM key is
pressed in. Display shows Ad (SW1=Off)
or OP (SW1=On).
Attention : Do not modify Op setting
(Op=5).
Press PGM key until display shows Sd
and default value 10°C or the last
recorded one.
Select the desired temperature with
t or s button. ( ex: 12 °C ).
Press RET key to exit from programming
the STBY mode temperature.