Toro 02003 Operator's Manual page 12

Table of Contents

Advertisement

Before Operating
2.
Fill the tank to about one inch below the top of the
tank, not the filler neck, with No. 2 diesel fuel. Then
install the cap.
1. Fuel Tank Cap
DANGER
Because diesel fuel is flammable, use caution when
storing or handling it. Do not smoke while filling the
fuel tank. Do not fill the fuel tank while the engine is
running, hot, or when the machine is in an enclosed
area. Always fill the fuel tank outside and wipe up any
spilled diesel fuel before starting the engine. Store fuel
in a clean, safety-approved container and keep the cap
in place. Use diesel fuel for the engine only; not for
any other purpose.
DRAINING WATER FROM FUEL
FILTER/WATER SEPARATOR
(Fig. 4)
Any water accumulation should be drained from the fuel
filter/water separator before each use.
1.
Position machine on a level surface and stop the
engine.
2.
Open the drain valve on the fuel filter/water
separator and drain any accumulated water.
12
1
Figure 3
1. Drain valve
NOTE: Because the accumulated water will be mixed
with diesel fuel, drain the fuel filter into a suitable
Container and dispose of properly.
CHECK THE HYDRAULIC SYSTEM
FLUID
The hydraulic system is designed to operate on SAE
10W-30 engine oil or, as a substitute, SAE 10W-40
engine oil. The reservoir is filled at the factory with 4.7 l
of 10W-30 engine oil. Check the oil level before first
starting the engine and daily thereafter.
1.
Position the machine on a level surface and stop the
engine.
2.
Remove the access panel to expose the hydraulic
system dipstick filler cap.
1. Access panel
3.
Remove the dipstick cap from the filler neck and
wipe it with a clean cloth. Insert the dipstick cap
1
Figure 4
1
Figure 5

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Grounds pro 2000-d

Table of Contents