(9) To change the air flow direction not to blow directly onto your body.
To change the air
When to use this function?
flow direction
Pressing and holding
Use this function if you don't
want the air from the indoor
VANE CONTROL
unit to blow directly onto your
button for 2 seconds
body.
or more causes
• Depending on the shape of
the horizontal vane
the room,the air may blow
to reverse and
directly onto your body.
move to horizontal
position.
• Press VANE CONTROL
button again to return the
vane to the previously-set
position.
Horizontal
position
NOTE:
• If you make the air flow not to blow directly onto your body by pressing VANE CONTROL button,
the compressor stops for 3 minutes even during the operation of the air conditioner.
• The air conditioner operates with decreased air flow until the compressor turns on again.
(10) ECONO COOL (
When ECONO COOL button is pressed in COOL mode, set temperature is automatically set 2°C higher than that in
COOL mode.
Also the horizontal vane swings in various cycle according to the temperature of indoor heat exchanger(RT12).
SWING operation makes you feel cooler than set temperature. So, even though the set temperature is higher than that
in COOL mode, the air conditioner can keep comfort. As a result, energy can be saved.
ECONO COOL operation is cancelled when ECONO COOL button is pressed once again or VANE CONTROL
button is pressed or change to other operation mode.
<SWING operation>
In swing operation of ECONO COOL operation mode, the initial air flow direction is adjusted to "Horizontal".
According to the temperature of indoor coil thermistor RT12 at starting of this operation, next downward blow time is
decided. Then when the downward blow has been finished, next horizontal blow time is decided.
For initial 10 minutes the swing operation is performed in table G~H for quick cooling.
Also, after 10 minutes when the difference of set temperature and room temperature is more than 2:, the swing oper-
ation is performed in table D~H for more cooling.
The air conditioner repeats the swing operation in various cycle as follows.
Temperature of indoor
coil thermistor RT12
A
B
C
D
E
F
G
H
Downloaded from AC-Manual.com Manuals
The air conditioner starts the
cooling or drying operation
approx. 3 minutes after the
vane has moved to the hori-
zontal position.
When VANE CONTROL
button is pressed again,
the vane returns to the
previously-set position
and the air conditioner
starts the cooling or
drying operation in
approx. 3minutes.
) operation (ECONOmical operation)
15°C or less
15°C to 17°C
17°C to 18°C
18 °C to 20 °C
20°C to 21°C
21°C to 22°C
22°C to 24°C
more than 24°C
COOL/DRY
The air conditioner starts heat-
ing operation approx. 3 minutes
after the vane has moved to the
horizontal position.
• Sometimes the area
around your feet may not
warm. To warn the area
around the feet, set the
horizontal vane to
(AUTO) or the downward-
blowing position.
• When VANE CONTROL
button is pressed again,
the vane returns to the
previously-set position
and the air conditioner
starts the heating operation
in approx. 3minutes.
Downward blow time
(second)
2
5
8
11
14
17
20
23
10
HEAT
Horizontal blow time
(second)
23
20
17
14
11
8
5
2