Electrical Specifications - Bard I30A1DA Installation Instructions Manual

Table of Contents

Advertisement

Rated
No. Field
MODEL
Volts, Hertz
Power
& Phase
Circuits
I30A1DA0Z
1
A05
230/208-1
1
A10
1
I30A1DB0Z
1
B06
230/208-3
1
B09
1
I30A1DC0Z
1
C06
460-3
1
C09
1
I36A1DA0Z
1
A05
1
230/208-1
A10
1
A15
1 or 2
I36A1DB0Z
1
B06
1
230/208-3
B09
1
B15
1
I36A1DC0Z
1
C06
1
460-3
C09
1
C15
1
I42A1DA0Z
1
A05
1
230/208-1
A10
1
A15
1 or 2
I42A1DB0Z
1
B06
1
230/208-3
B09
1
B15
1
I42A1DC0Z
1
C06
1
460-3
C09
1
C15
1
I48A1DA0Z
1
A04
1
A05
1
230/208-1
A10
1
A15
1 or 2
A20
1 or 2
I48A1DB0Z
1
B06
1
B09
230/208-3
1
B15
1
B18
1
I48A1DC0Z
1
C06
1
C09
460-3
1
C15
1
C18
1
I60A1DA0Z
1
A05
1
A10
230/208-1
1
A15
1 or 2
A20
1 or 2
I60A1DB0Z
1
B06
1
B09
230/208-3
1
B15
1
B18
1 or 2
I60A1DC0Z
1
C06
1
C09
460-3
1
C15
1
C18
1
 These "Minimum Circuit Ampacity" values are to be used for sizing the field power conductors. Refer to the National Electric Code (latest
revision), article 310 for power conductor sizing.
Caution: When more than one field power conductor circuit is run through one conduit, the conductors must be derated. Pay special
attention to note 8 of table 310 regarding Ampacity Adjustment Factors when more than three conductors are in a raceway.
 Maximum size of the time delay fuse or circuit breaker for protection of field wiring conductors.
 Based on 75°C copper wire. All wiring must conform to the National Electrical Code and all local codes.
TABLE 2

Electrical Specifications

Single Circuit
Maximum
Minimum
Field
External
Circuit
Power Wire
Fuse or Ckt.
Ampacity
Size
Brkr.
22
35
8
32
35
8
58
60
6
17
25
10
23
25
10
32
35
10
9
10
14
13
15
14
18
20
12
26
40
8
32
40
8
58
60
6
84
90
4
22
30
10
23
30
10
32
35
8
51
60
6
11
15
14
13
15
14
18
20
12
28
30
10
30
45
8
32
40
8
58
60
6
82
90
4
25
35
8
25
35
8
32
35
8
52
60
6
12
15
14
14
15
14
19
20
12
28
30
10
34
50
8
34
50
8
34
50
8
59
60
6
85
90
3
110
110
2
26
35
8
26
35
8
34
35
8
53
60
6
53
60
6
12
15
12
14
15
12
19
20
12
29
30
10
33
35
8
44
60
8
44
60
6
59
60
6
96
100
3
112
120
2
31
45
8
31
45
8
35
45
8
58
60
6
63
70
6
15
20
12
15
20
12
19
20
12
29
30
10
29
30
10
Minimum
Maximum
Ground
Circuit
External Fuse or
Ampacity
Ckt. Breaker
Wire
Ckt. A Ckt. B
Ckt. A
10
10
10
10
10
10
14
14
12
10
10
10
8
26
52
40
10
10
10
10
14
14
12
10
10
10
10
8
56
52
60
10
10
10
10
14
14
12
10
10
10
10
10
8
35
52
45
6
59
52
60
10
10
10
10
10
12
12
12
10
10
10
10
10
8
44
52
60
6
60
52
60
10
10
10
10
8
31
54
45
12
12
12
10
10
Dual Circuit
Field Power
Ground Wire
Wire Size
Size
Ckt. B
Ckt. A Ckt. B Ckt. A Ckt. B
60
8
6
10
60
6
6
10
60
8
6
10
60
6
6
10
60
8
6
10
60
6
6
10
60
8
6
10
Manual 2100-597G
Page
7 of 68