Installing The Roof Exit For Air Pipe - Buderus Logano plus GB312 Applications Manual

Gas condensing boiler
Table of Contents

Advertisement

2 0 |
5
1
2
2
12 min
Fig. 11 Design of air supply or exhaust pipe wall exit
1
Outer wall retaining plate
2
Sealant
3
T-piece or 4) 90° elbow
4
90° elbow - down turned
5
Inner wall centering and retaining plate
6
Tee termination (optional)
Note:
For exhaust applications, the distance for clearance
to combustible must be maintained. Refer to NFPA54 (ANSI
Z223.1) for details.

5.3 Installing the roof exit for air pipe

To prevent possible recirculation of fl ue gas, the fl ue system
installer must take account of effects such as the prevailing
wind conditions, any eddy zones, the specifi cs of
the site, etc. in the design of the fl ue and air supply systems.
Buderus can not be held responsible for such
potentially detrimental effects on boiler operation. The
clearances detailed or illustrated should be seen as the
absolute minimum and may in some circumstances not be
adequate for specifi c installations.
2
1
Fig. 12 Design of air pipe roof exit
1
T-piece or 2) 90° elbow
3
Flue outlet
B
Minimum horizontal distance from air intake of another
appliance = 10 ft, minimum distance from own air intake
for directly vented appliances = 4 ft.
Technical specifi cations are subject to change without prior notice
6
3
4
B
3
4 min
A
4 min
7 747 010 720-16.3
GB312 Applications Manual
Contact vent pipe manufacturer for
installation guidelines to support vertical
lengths of pipe.
Logano plus GB312 applications manual | 04.2008