10
3.1

LOCATION AND CLEARANCES

DO NOT INSTALL INTO ANY AREA HAVING A HEIGHT LESS THAN 7 FEET (2.1M) (CEILING OF
ENCLOSURE TO APPLIANCE BOTTOM, EXCLUDING HEARTH HEIGHT).
The appliance is shipped with a set-up face that is 1/8" (38m) larger
on the top, bottom and each side than the faceplate. Leave the set-up
face in place to act as a template when installing the fi nishing face.
IMPORTANT
This appliance, fully dressed, weighs 850 lbs (386kg). Ensure there is
adequate fl oor support for the appliance, chimney and facing material.
Some material could weigh thousands of pounds.
We recommend that the appliance be secured to the fl oor in
all cases.
Using the door opening as a datum, level the appliance by
shimming underneath the appliance. Remove and discard the
lifting handles. Bend the tabs down and secure the appliance to
the fl oor.

3.1.1 VENTILATION OPENINGS

The appliance enclosure must be provided with suffi cient air circulation to avoid a fi re hazard. Install ventilation
grilles (minimum openings of 40 sq. inches (0.03 sq. meters)) at both fl oor and ceiling levels of the enclosure.
These grilles must not restrict the fl ow of heat by more than 25%. Do not install into any area having a
height less than 7 ft (2m) (ceiling of enclosure to appliance bottom, excluding hearth height). The location
of windows, doors and the traffi c fl ow in the room where the stove is to be located should be considered. If
possible, you should choose a location where the chimney will pass through the house without cutting a fl oor
or roof joist.